6000PLUS/TSR2

 

  • Protec AlgoTec™ 6000 Protocol

  • Loop Powered

  • High Output Electronic Sounder

  • Low Current Consumption

  • Integral Short Circuit Isolator

  • Weatherproof to IP65

  • Choice of Colours

  • Approved to EN54 Part 3 & 17

 

Description

For the ultimate method of alerting building occupants of the incidence of an emergency, the Protec Algo-Tec™ 6000PLUS/TSR2 is equipped with an integrated voice enhanced sounder. The talking sounder is capable of delivering synchronised alert and evacuate messages around a building, removing any ambiguity, particularly for anyone unfamiliar with the building alert and evacuation strategy, enabling a more prompt and safe building evacuation.
When combined with the LED beacons and multi-sensor fire detection technology, we are able to provide the ultimate and most innovative fire detection PLUS alarm system for buildings.
 

The 6000PLUS/TSR2 voice enhanced talking sounder is available with seven voice messages plus ‘bell’ sound in addition to the three fire alarm tones compatible with the Protec range of electronic sounders. All voice messages, bell sound and alarm tones are selectable from the control panel, along with volume adjustment. A loop short circuit isolator is incorporated to enhance the system integrity.
 

Available in either Red or White body colours, the 6000PLUS/TSR2 has an IP65 rating making the product suitable for mounting internally or externally. An optional deep base allows surface mounted cable to be terminated directly into the sounder.
 

The 6000PLUS/TSR2 is an ideal addition to the fire alarm system providing a clear spoken message to inform the occupant of a fire alarm condition and is compatible for use with the Protec 6000PLUS sensor range.

Standard Messages
  1. “Attention please, attention please. Fire has been reported in the building, please leave the building immediately by the nearest exit”

  2. “May I have your attention please, an incident has been reported in the building please listen for further instructions”

  3. “Attention, attention. This is an emergency. Please leave the building by the nearest available exit”

  4. “This is a test message, no action is required”

Technical

Environment

-10°C to 55ºC (95% RH non condensing)

Ingress Protection

IP65

Weight  

244g

Loop Powered

Yes

Loop Standby Load

0.7mA

Loop Alarm Load

6mA (9mA with Bell Sound)

Loop Voltage

18 - 28V

Loop Isolator

Yes

Sounder Volume

93dB(A) (High), 75dB(A) (Mid), 65dB(A) (Low)*

Output Details

Piezo sounder. Sounder tone Voice Message and volume selectable at the control panel

Construction

ABS Base & Body

Applicable Standards

Designed to EN54 Part 3 & 17
Compliant to CE and LVD standards

Device Protocol

Algo-Tec™ 6000PLUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* measured at one metre on axis

Diagram

PCB Connection Details Rear View (Gland Box Removed)

Other

Tone Options

Bell Tone: 800Hz
Warble Tone: 990Hz(250ms), 665Hz(250ms)
Continuous Tone: 990Hz
Pulse Tone: 990Hz(500ms), Silence(500ms)
 

Tone Volume Options

The tone and volume are selectable at the control panel (measured at one metre):
High: 100dB(A), Mid: 95dB(A), Low: 75dB(A)
 

15LHK0960-01